Products
Inner Resolver Standard Type
HOME > Products > Inner Resolver Standard Type

SPECIFICATION

Item Specification
Target Construction Target Fixed Screw Type Target Guide Pipe Type
Model IR18G IR18C IR30C
Cylinder rod diameter that can be interpolated(mm) φ28~ φ36~ φ45~
Target Guide Pipe Diameter(mm) - φ18 φ30
Fixed Screw Size M18X1.5 - -
Target Rid Diameter(mm) φ3 φ3 φ6
Backward limit size *1 20 20 35
Maximum Stroke(mm) *2 1200 1200 1600
Rated Pressure(MPa) 21
Maximum Cable Length(m) 200
Protection Grade IP67
*1. The backward limit size means a necessary size on the sensor flange edge and the piston edge in the state to finish the return of the piston. *2. Please consult for the size that exceeds the specification.

Item Specification
Model IR18C(G)12W / IR30C12W IR18C(G)51W / IR30C51W
Absolute Pitch(mm) 12.8 51.2
Resolution(μm) 1.56 6.25
Repetition Accuracy(μm) 10
Linearity(mm) 0.15+L/5000(L:stroke)
Operating Temperature(°C) -10~120
Storage Temperature(°C) -20~120
Vibration Resistance Radial 0.49×102~1.96×102m/s2(10~150Hz)*
Thrust 1.96×102m/s2(10~150Hz)*
Shock Resistance Radial 0.98×103m/s2*
Thrust 4.9×103m/s2*
Insuration Resistance 20MΩmin. Input and Case
(measured by 500 VDC insulation resistance tester)
Applicable Converter RCP-WM Series
* The case of stroke : 500mm

MODEL CODE

MODEL CODE
Item Code Description
1 Model Classification IR INNER RESOLVER
2 Target Guide Pipe Diameter(mm) 18 φ18
30 φ30
3 Target Construction C Target Guide Pipe Type
G Target Fixed Screw Type
4 Abusolute Pitch(mm) 12 12.8(standard)
51 51.2(standard)
8 8.192(high accuracy)
5 Excitation Method W Two-phase(standard)
T Three-phase(high accuracy)
6 Operating Temperature(°C) S -10~80
H -10~120
7 Stroke(mm) *Omitting decimals
8 Lead Cable Length(m)

OUTLINE

TARGET GUIDE PIPE TYPE

IR18C12W


IR30C12W

Method of installing sensor in cylinder

TARGET GUIDE PIPE TYPE

TARGET GUIDE PIPE TYPE

CONVERTER

RCP:Binary Output
RCP:Binary + Pulse Output
HCP

SPECIFICATION

Item Specification
Series RCP Series HCP Series
Output Type Binary Binary + Pulse
(Composite)
Binary Pulse
High-Accurate
Sensor-enabled
Converters
Input/Output
(DC24V)
RCP-WM-100-B0 RCP-WM-100-B0P RCP-WM-024-B0 HCP-WM-024-P
Input/Output
(DC48V)
RCP-WM-100-B1 RCP-WM-100-B1P RCP-WM-024-B1
Position Detection Format Phase Difference Semi-Absolute Postion Detection -
Resolution 13bit/pitch(8192 division) 12bit/pitch(4096 division)
Position Sencing Stroke 0-2047 pitch -
Frequency Response(kHz) 5 5
Input Signal Data Renewal Stop, Zero Position Setting, Error Reset -
Output Signal Binary Photo-coupler isolation NPN transister open collecter 24bit+timing signal -
Pulse - Line Driver Pulse Output + Busy Output
(Select from A/B Phase,
2 Pulse, and Symbol + Pulse)
- Line-Driver
other Alarms* Alarms and Pulse Output Error* Alarms* Alarms*
Binery Data Update Cycle Select from 0.2ms/0.4ms/0.8ms/1.6ms/3.2ms/6.4ms -
Pulse Frequency Response - 2MHz maxmum - 2.5MHz maximum
Supply Power(V) AC100~240(+10%/-15%) DC24 DC24
Power Consumption(VA) 46 or less 0.47A or less (Currnt Consumption) 0.1A or less (Currnt Consumption)
Operating Temperature(°C) 0~55 0~55 0~55
Exterior Dimensions(mm) 50(W)×270(H)×140(D) 65(W)×270(H)×140(D) 50(W)×270(H)×140(D) 30(W)×180(H)×100(D)
Weight(kg) Approximately 1.4 Approximately 1.6 Approximately 1.3 Approximately 0.5
*Alarm signal output transister turns ON during nomal operating Positive logoc.

CABLE

SPECIFICATION

Item Two-Phase
Standard Type
Two-Phase
Heat Resistant Type
Material Tinned annealed copper wire
Rated Temperature(°C) 60 150
Number of Construction 40/0.08
Norminal Cross-Sectional Area(mm2) 0.2
Insulater Polyethylene Flourine Resin
Sheath Vinyl Flourine Resin
Conductor Resistance(Ω/km) 101 103
Sheath External Diameter(mm) 8.2 7.4

CROSS SECTION

CROSS SECTION

CONNECTION

CONNECTION

Contact us:
TEL.+81-75-325-2888
Contact us by email

Page Top