CLP35-008
CLP80-020


SPECIFICATION

SENSOR

Item Specification
Model CLP35-008-1 CLP80-020-1
Outer Diameter(mm) φ3.5 φ8.0
Measurable Length(mm) 8 20
Mechanical Stroke(mm) 10 24
Linearity ±2%/F.S. or less ±1.5%F.S. or less
Operating Temperature(°C) -10~70(no dew condensation) -10~70(no dew condensation)
Temperature Influence *1 1.5% of F.S/°C or less 1% of F.S/°C or less
Lead Cable PFA Coating φ1.3 2m PVC Coating φ2.4 2m
*1 Between 0 and 60 Degee Celsius.

AMPLIFIER

Item Specification
Power Supply DC12~24V *2 ripple : ±10%
Current Consumption 40mA or less
Signal Output Voltage 1~5V Analogue output
Resolution Approx. 1/2000 of the entire measurement area
Response Frequency Approx. 4kHz
Operating Temperature(°C) -20~80
Temperature Influence *1 0.025% of F.S/°C or less
Power Supply/Signal Cable Specified Cable : PVC coating φ4 2m
Color
Brown : Power Supply V+ / Black : Power Supply GND
Orange : Signal GND / Blue : Signal V+
*1 Between 0 and 60 Degee Celsius.
*2 CVS5(Option) : DC9~16V

CONTENT OF STANDARD SET

SENSOR
AMPLIFIER(CV05)
POWER SUPPLY & SIGNAL CABLE(2m)

MODEL CODE

MODEL CODE
Item Code Description
1 Model Classification CLP Push Rod Pulse Coder
2 Sensor Diameter(mm) 35 φ3.5
80 φ8.0
3 Stroke(mm) 008 8
020 20
4 Amplifier Model 1 CV05
2 CVS5

OUTLINE

CLP35-008-1


CLP80-020-1


CVS5

MOUNTING, NOTICE

  • This sensor utilizing magnetic sensors for the hole in the metal and pipe sensor to insert and change the output.
  • Please hold by "Sensor fixation part (fixed range)" described in the specification chart when you fix. In that case, when a local tightening is done with the screw etc. , the sensor might be damaged.
  • When the same kind of sensor is used with two or more axes, the interference noise might be generated in the output. In that case, please leave space by 50mm or more and set it up. And, when two or more axes are set up in the same conductor (metallic case), the interference noise might be generated.
  • In that case, please insulate each sensor from the case. A synchronous driving on the amplifier side or the production of a special amplifier is received in situations such as the sensor interval cannot be taken or not being possible to insulate it.

OUTPUT CHARACTERISTIC

CLP35-008-1

OUTPUT CHARACTERISTIC

Contact us:
TEL.+81-75-325-2888
Contact us by email

Page Top